Air Conditioning & Heat Pump Inspection Glossary of Terms and Conditions
A-coil - An evaporator coil shaped like the letter A, commonly installed inside an air handler or furnace plenum.
Air conditioning - A system that cools indoor air by removing heat and transferring it outdoors. Many systems also dehumidify the air.
Air gap - An open physical separation between a water outlet and the flood-level rim of a receiving fixture. It helps prevent contaminated water from flowing backward into the potable water supply.
Attic venting - Openings or systems that allow air to circulate through an attic, helping manage heat and moisture.
Backdrafting - The reversal of normal exhaust flow, allowing combustion gases to spill back into a building rather than vent outdoors.
Backflow preventer - A device designed to prevent water from flowing backward into a potable water supply.
Belt drive - A motor arrangement that uses a belt and pulleys to drive a fan or blower.
Capillary tube - A narrow, fixed-length tube that acts as a refrigerant metering device by restricting refrigerant flow into the evaporator.
Central thermostat - A temperature-control device that monitors indoor conditions and signals the heating or cooling system to operate.
Clothes dryer or water heater vent - An exhaust passage intended to carry moisture, lint, or combustion gases outdoors. It should not be connected to an air-conditioning condensate drain or used as a substitute for an approved ventilation system.
Combustion appliances - Appliances that burn fuel, such as natural gas, propane, or oil, to produce heat. They require appropriate combustion air and safe exhaust venting.
Compressor - The component of a refrigeration system that compresses refrigerant vapor and circulates it through the system.
Compressor life - The expected service life of an air-conditioning or heat-pump compressor. Actual lifespan depends on operating conditions, maintenance, installation, and equipment quality.
Compressor warranty - The manufacturer's warranty covering the compressor for a specified period, subject to its terms and conditions.
Condensate collection - The gathering of water produced when humid air passes over a cold evaporator coil and moisture condenses out of the air.
Condensate drain pan - A tray beneath an evaporator coil that collects condensation and directs it toward a drain.
Condensate pump - A small pump used to move collected condensate to a suitable drainage location when gravity drainage is not practical.
Condenser coil - The heat-exchange coil where hot refrigerant releases heat and condenses from vapor into liquid. In cooling mode, this is generally the outdoor coil.
Condenser fan - A fan that moves air across the condenser coil to help release heat into the outdoor environment.
Crankcase heater - An electric heating element that keeps refrigerant from migrating into and diluting compressor oil during periods when the compressor is not operating.
Dehumidification - The removal of moisture from indoor air, commonly accomplished as warm humid air passes over a cold evaporator coil.
Direct drive - A fan or blower arrangement in which the motor is directly connected to the fan wheel, without a belt and pulley system.
Duct insulation - Insulation applied to heating and cooling ducts to reduce unwanted heat transfer and help prevent condensation.
Ductwork capacity - The amount of air that a duct system can deliver or return while maintaining suitable airflow and pressure. Capacity depends on duct dimensions, layout, resistance, and equipment requirements.
Evaporative coolers - Cooling devices that lower air temperature by evaporating water into an airstream. They work best in hot, dry climates and add moisture to the air.
Evaporator coil - The heat-exchange coil where liquid refrigerant absorbs heat and evaporates into a gas. In cooling mode, it is generally located indoors.
Evaporator fan - A fan that moves indoor air across the evaporator coil to transfer heat from the air to the refrigerant.
Excess current - Electrical current drawn by equipment beyond its expected operating range, potentially indicating a mechanical, electrical, or equipment problem.
Expansion device - A component that controls the flow of refrigerant into the evaporator while reducing its pressure. Examples include capillary tubes, fixed orifices, and thermostatic expansion valves.
Filter/dryer - A refrigerant-system component that removes moisture, contaminants, and particles from the refrigerant.
Fixed orifice (accurator) - A fixed-size opening that meters refrigerant flow into the evaporator. An accurator is a type of fixed-orifice metering device.
Flex duct - Flexible ductwork, usually consisting of a wire-supported inner liner, insulation, and an outer vapour barrier, used to distribute conditioned air.
Full Load Amperage (FLA) - The current a motor is designed to draw when operating at its rated full load under specified conditions. It is a nameplate rating, not necessarily the actual current drawn at all times.
Ground-cooled systems - Cooling systems that use the relatively stable temperature of the ground as a heat sink or heat source. Ground-source heat pumps are a common example.
High returns - Return-air openings located high on walls or near ceilings, where they draw warmer air from the upper part of a room.
Humidifier duct damper - A damper used to control airflow through ductwork serving a whole-house humidifier.
Inadequate cooling - A condition in which an air-conditioning system fails to maintain the desired indoor temperature or provide sufficient cooling under expected operating conditions.
Inoperative - Not functioning or failing to operate as intended.
Latent heat - Heat absorbed or released during a change of state, such as water evaporating or refrigerant condensing, without a corresponding change in temperature during the phase change.
Latent heat of vaporization - The amount of heat required to convert a liquid into a gas without changing its temperature during the phase change.
Liquid line - The refrigerant line that carries high-pressure liquid refrigerant from the condenser toward the expansion device.
Louvers - Angled slats or blades installed in an opening to direct airflow while helping limit the entry of rain, debris, or unwanted air.
Low returns - Return-air openings located near floor level, where they draw cooler air from the lower part of a room.
Noise/vibration - Unusual sound or physical movement produced by HVAC equipment. Possible causes include loose components, unbalanced fans, worn bearings, compressor problems, or improper installation.
N-coil - An evaporator coil arranged in an N-shaped configuration, often used in air handlers or furnace installations.
No electrical disconnect - A condition in which the required local electrical disconnecting means is missing or not readily accessible near the HVAC equipment.
One ton - A unit of cooling capacity equal to 12,000 British thermal units per hour (BTU/h). It originated from the approximate amount of heat required to melt one ton of ice in 24 hours.
Out of level - Equipment that is not installed level. Depending on the equipment design, this can affect drainage, operation, vibration, or service life.
Oversized - Equipment with a capacity greater than needed for the space or building. Oversized air conditioners may cool quickly but run for shorter cycles, potentially reducing humidity control and efficiency.
Rated Load Amperage (RLA) - A compressor electrical rating used by manufacturers to identify an expected operating-current value under specified conditions. It is not necessarily the same as the measured running current.
Receiver - A storage vessel in a refrigeration system that holds liquid refrigerant leaving the condenser before it flows toward the metering device.
Refrigerant - A fluid that circulates through a refrigeration or heat-pump system, absorbing heat in one part of the system and releasing it in another.
Return ducts - Ducts that carry indoor air back to the heating or cooling equipment to be filtered, heated, cooled, or otherwise conditioned.
Rotary, spray and drip - Types of evaporative-cooling arrangements. They use different methods of exposing water to moving air to promote evaporation and cooling.
Rust - Iron oxide corrosion that can develop on metal components exposed to moisture and oxygen. It may affect equipment cabinets, coils, supports, and other metal parts.
Short cycling - Frequent starting and stopping of heating or cooling equipment over short periods. It can result from oversized equipment, thermostat problems, restricted airflow, or equipment faults.
Sight glass - A transparent viewing window in a refrigerant line, often used to observe refrigerant condition or moisture indicators where the system design includes one.
Single pass - An evaporative-cooling arrangement in which air passes through the cooling medium once before being discharged into the building or space.
Sludge - Thick deposits of oil, dirt, moisture-related contaminants, or degraded material that can accumulate in refrigeration equipment and interfere with operation.
Slugging - A compressor condition in which liquid refrigerant or oil enters the compressor cylinders or compression chamber. Because liquids do not compress like gases, slugging can cause severe mechanical damage.
Suction line - The refrigerant line that carries low-pressure refrigerant vapor from the evaporator back to the compressor.
Supply ducts - Ducts that deliver heated or cooled air from the HVAC equipment to rooms throughout a building.
Swamp coolers - Another name for evaporative coolers, which cool air by evaporating water.
Temperature drop - The difference in air temperature measured between the return-air and supply-air sides of an operating cooling system. It can help assess system performance, although the expected range depends on operating conditions.
Thermostatic expansion valve - A refrigerant metering device that regulates refrigerant flow into the evaporator based on the refrigerant's superheat, helping maintain appropriate evaporator operation.
Trap - A curved section of drain piping that retains water to prevent air or gases from passing through. In condensate drainage, traps may be required depending on the equipment's pressure conditions.
Undersized - Equipment or components with insufficient capacity for the intended application. Undersized HVAC equipment may struggle to maintain the desired indoor temperature.
Undersized wire - Electrical wiring with a conductor size inadequate for the equipment's current requirements, circuit length, or applicable electrical code.
Water-cooled systems - Cooling systems that transfer heat to water rather than directly to outdoor air.
Water-cooled condenser coil - A heat exchanger that transfers heat from refrigerant to circulating water, allowing the refrigerant to condense.
Whole-house fan - A large fan that draws outdoor air through open windows and exhausts indoor air into the attic, typically helping cool a house when outdoor temperatures are lower than indoor temperatures.
Whole-house fans - Fans designed to ventilate a home by drawing cooler outdoor air through living spaces and exhausting warmer indoor air into the attic or outdoors.
Wrong breakers - Circuit breakers that are incorrectly sized or unsuitable for the HVAC equipment, potentially compromising electrical protection and safe operation. Breaker selection must follow equipment specifications and applicable electrical requirements.
|
|
|